Frymaster BID80 Series Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Friteuses Frymaster BID80 Series. Frymaster BID80 Series User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 62
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
PARTS LIST
INCLUDED
Frymaster, a member of the Commercial Food Equipment Service Association, recommends
using CFESA Certified Technicians.
Price: $10.00
24-Hour Service Hotline 1-800-551-8633
819-5896
APRIL 2002
BID80 Series Gas Fryers
Installation & Operation Manual
BID80 Series With Built-In Filtration
Vue de la page 0
1 2 3 4 5 6 ... 61 62

Résumé du contenu

Page 1 - BID80 Series Gas Fryers

PARTS LISTINCLUDEDFrymaster, a member of the Commercial Food Equipment Service Association, recommendsusing CFESA Certified Technicians.Price: $10.002

Page 2

BID80 SERIES GAS FRYERSCHAPTER 2: IMPORTANT INFORMATION2-22.4 Pre-Installation (cont.)2. Frymaster BID80 Series gas fryers require 120VAC 60 cycle

Page 3

BID80 SERIES GAS FRYERSCHAPTER 2: IMPORTANT INFORMATION2-32.4 Pre-Installation (cont.)3. CE/EXPORT STANDARDS: Fryer installation must conform with

Page 4 - TABLE OF CONTENTS

BID80 SERIES GAS FRYERSCHAPTER 2: IMPORTANT INFORMATION2-42.7 Receiving and Unpacking EquipmentA. Check that the container is upright. Use an outwa

Page 5 - TABLE OF CONTENTS (CONT.)

BID80 SERIES GAS FRYERSCHAPTER 3: INSTALLATION3-13.1 Installing the FryerA. Initial Installation: If the fryer is installed with legs, do not push

Page 6 - CHAPTER 1: INTRODUCTION

BID80 SERIES GAS FRYERSCHAPTER 3: INSTALLATION3-23.3 Installing Casters and LegsA. Install casters and/or legs near where the fryer is to be used,

Page 7 - 1.6 Service Personnel

BID80 SERIES GAS FRYERSCHAPTER 3: INSTALLATION3-33.4 Gas Connections DANGERBefore connecting new pipe to this appliance the pipe must be blown out t

Page 8

BID80 SERIES GAS FRYERSCHAPTER 3: INSTALLATION3-43.4 Gas Connections (cont.) DANGERAll connections must be sealed with a joint compound suitable for

Page 9

BID80 SERIES GAS FRYERSCHAPTER 3: INSTALLATION3-53.4 Gas Connections (cont.)E. Manifold Pressure: Only qualified personnel should check the manifo

Page 10 - 2.4 Pre-Installation (cont.)

BID80 SERIES GAS FRYERSCHAPTER 3: INSTALLATION3-63.4 Gas Connections (cont.)3. If disconnection of the restraint is necessary, this restraint must

Page 11

BID80 SERIES GAS FRYERSCHAPTER 4: FRYER OPERATIONS4-14.1 Initial Start-up WARNINGThe on-site supervisor is responsible for ensuring that operators a

Page 12

Please read all sections of this manual and retain for future reference. NOTICE This appliance is intended for professional use only and is to be o

Page 13 - CHAPTER 3: INSTALLATION

BID80 SERIES GAS FRYERSCHAPTER 4: FRYER OPERATIONS4-24.1.1 Pilot Lighting Procedures, Electronic Ignition Systems (cont.)3. The electric module wil

Page 14

BID80 SERIES GAS FRYERSCHAPTER 4: FRYER OPERATIONS4-34.2 Boil-Out Procedure (cont.)C. Press the switch. will appear in the left display.D. En

Page 15 - 3.4 Gas Connections

BID80 SERIES GAS FRYERSCHAPTER 4: FRYER OPERATIONS4-44.3 Final Preparation (cont.) WARNINGNEVER set a complete block of solid shortening on top of t

Page 16 - 3.4 Gas Connections (cont.)

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-1 WARNINGDrawings and photos used in this manual are intended to illustrate operational,cleani

Page 17

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-25.1 GeneralFrymaster BID80 Series fryers come equipped with a built-in filtration system. P

Page 18 - 3.5 Electrical Connections

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-35.2 Filtration PreparationOn initial installation and before each use, remove all loose part

Page 19 - CHAPTER 4: FRYER OPERATIONS

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-45.2.1 Assembling the Filter (cont.)Assemble the filter as follows:1. Place the support grid

Page 20 - 4.2 Boil-Out Procedure

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-55.2.1 Assembling the Filter (cont.)4. Sprinkle 8 ounces of filter powder on thefilter sheet

Page 21 - 4.3 Final Preparation

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-65.2.2 Installing the FilterSlide the filter inside the fryer cabinet. Ensurethe male-female

Page 22 - WARNING

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-75.3.2 Filtering ToolsAssemble tools to be used for filtering. These are supplied with the f

Page 23

DANGERAdequate means must be provided to limit the movement of this appliance without dependingupon the gas line connection. Single fryers equipped

Page 24 - 5.1 General

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-85.4 Operating the Filter (cont.) DANGERDo not drain more than one frypot at a time into the

Page 25 - 5.2 Filtration Preparation

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-95.4.2 Filter Operation CAUTIONNEVER operate the filter unit unless cooking oil/shortening is

Page 26

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-105.4.2 Filter Operation (cont.)4. After ensuring the filter pan is correctlypositioned unde

Page 27 - Crumb screen properly placed

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-115.4.2 Filter Operation (cont.)6. Oil will begin to pump from the filter paninto the frypot

Page 28

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-125.4.2 Filter Operation (cont.)9. After all oil is pumped back into the frypot,bubbles will

Page 29 - 5.4 Operating the Filter

BID80 SERIES GAS FRYERSCHAPTER 5: BUILT-IN FILTRATION5-135.4.2 Filter Operation (cont.)12. Do not allow crumbs to accumulate in thecrumb tray. The

Page 30

BID80 SERIES GAS FRYERSCHAPTER 6: COMPUTER OPERATION6–16.1 Operating Fryers with Computer Magic III.5 Computers12453867ITEM DESCRIPTION1 Lighted Dis

Page 31

BID80 SERIES GAS FRYERSCHAPTER 6: COMPUTER OPERATION6–26.1.1 Equipment Setup and Shutdown ProceduresSetup WARNINGFill the frypot to the bottom OIL L

Page 32

BID80 SERIES GAS FRYERSCHAPTER 6: COMPUTER OPERATION6–36.1.1 Equipment Setup and Shutdown Procedures (cont.)d. " " indicating that the fr

Page 33

BID80 SERIES GAS FRYERSCHAPTER 6: COMPUTER OPERATION6–46.1.1 Equipment Setup and Shutdown Procedures (cont.)5. At this time, the hold time will be

Page 34

BID80 Series Gas FryersInstallation & Operation ManualTABLE OF CONTENTS Page #1. INTRODUCTION

Page 35

BID80 SERIES GAS FRYERSCHAPTER 6: COMPUTER OPERATION6–56.2 Programming the Computer Magic III.5 Computer (cont.)Sensitivity adjusts computer-cooking

Page 36

BID80 SERIES GAS FRYERSCHAPTER 6: COMPUTER OPERATION6–66.2.1 Boil Feature (cont.)2. To program computer for boil feature, press either switch.3. P

Page 37

BID80 SERIES GAS FRYERSCHAPTER 7: PREVENTATIVE MAINTENANCE7-17.1 General DANGERNever attempt to clean the fryer during the cooking process or when t

Page 38 - CAUTION

BID80 SERIES GAS FRYERSCHAPTER 7: PREVENTATIVE MAINTENANCE7-27.4 Periodic/AnnualThis appliance should be inspected and adjusted periodically by qual

Page 39 -

BID80 SERIES GAS FRYERSCHAPTER 7: PREVENTATIVE MAINTENANCE7-37.4 Periodic/Annual (cont.)Built-in Filtration (cont.):• Check filtration system integ

Page 40

BID80 SERIES GAS FRYERSCHAPTER 8: TROUBLESHOOTING8-18.1 General DANGERHot cooking oil/shortening will cause severe burns. Never attempt to move thi

Page 41

BID 80 SERIES GAS FRYERSCHAPTER 8: TROUBLESHOOTING8-28.2 Pilot Burner Malfunction (cont.)4. Check all connections for cleanliness and security.C.

Page 42

BID 80 SERIES GAS FRYERSCHAPTER 8: TROUBLESHOOTING8-38.3 Main Burner Malfunctions (cont.)D. Fryer will not reach the temperature setting and/or run

Page 43 - 7.4 Periodic/Annual

BID 80 SERIES GAS FRYERSCHAPTER 8: TROUBLESHOOTING8-48.4 Wiring Diagrams8.4.1 BID80 Series With Built-In FiltrationOPTIONAL HEAT TAPEHEAT TAPE-240V

Page 44 - 7.5 Stainless Steel Care

BID 80 SERIES GAS FRYERSCHAPTER 8: TROUBLESHOOTING8-58.4.2 BID80 Series Interface Board (Enlarged View)RIGHTTEMPPROBE4J387R-HEATLED 4RL-3R-GVLED 5RP

Page 45 - CHAPTER 8: TROUBLESHOOTING

BID80 Series Gas FryersInstallation & Operation ManualTABLE OF CONTENTS (CONT.) Page #5. BUILT-IN FILTRATION

Page 46 - 8.3 Main Burner Malfunctions

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-19.1 Accessories1 234 5ITEM PART # COMPONENT1 803-0301 Basket, Fry- 6 x 8-¾ x 16-¾ (Optional)2 810-21

Page 47

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-29.2 Cabinetry and Related Components1234567211514191320172322181612111098

Page 48 - 8.4 Wiring Diagrams

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-39.2 Cabinetry and Related Components (cont.)ITEM PART # COMPONENT1 211-2532 Side, Cabinet- Left2 210-

Page 49 - BID 80 SERIES GAS FRYERS

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-49.3 Computer and Related Components4 5 78911 106121 2 313 14151516

Page 50 - CHAPTER 9: PARTS LIST

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-59.3 Computer and Related Components (cont.)ITEM PART # COMPONENT1 210-3463 Panel, Control- BID802 106

Page 51

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-69.4 Drain Valve Components12378645101191213ITEM PART # COMPONENT1 106-1401 Bracket, Microswitch2 210-

Page 52

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-79.5 Filter Pan Components12346758ITEM PART # COMPONENT1 823-3750SP Filter Pan Assembly* 813-0684 Plug

Page 53

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-89.6 Frypot, Burners and Related Components123456789101112131414151516171819202829302526272122232431

Page 54

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-99.6 Frypot, Burners and Related Components (cont.)ITEM PART # COMPONENT1 823-3396SP Frypot, SS- 1-½&q

Page 55 - 9.4 Drain Valve Components

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-109.7 Oil Return Components2214134151617181920272824 25262221231To Frypot23445526678910101111121413129

Page 56 - 9.5 Filter Pan Components

BID80 SERIES GAS FRYERSCHAPTER 1: INTRODUCTION1-11.1 After PurchaseIn order to improve service, have the following chart filled in by the Frymaster

Page 57

BID80 SERIES GAS FRYERSCHAPTER 9: PARTS LIST9-119.7 Oil Return Components (cont.)ITEM PART # COMPONENT1 813-0460 Nipple, ½ x 3" NPT MB2 813-006

Page 58

THIS PAGE INTENTIONALLY LEFT BLANK

Page 59 - 9.7 Oil Return Components

Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106T

Page 60

BID80 SERIES GAS FRYERSCHAPTER 1: INTRODUCTION1-21.4 Computer Information (cont.)The user is cautioned that any changes or modifications not express

Page 61

BID80 SERIES GAS FRYERSCHAPTER 1: INTRODUCTION1-31.6.1 Definitions (cont.)B. Qualified Installation Personnel1. Qualified/authorized personnel are

Page 62 - APRIL 2002

BID80 SERIES GAS FRYERSCHAPTER 2: IMPORTANT INFORMATION2-12.1 Product DescriptionFrymaster BID80 Series gas fryers are energy-efficient, tube-style,