Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. 24-Hour Service Hotline 1
2-2 DANGER Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over and cause injury. The appliance area must b
2-3 2.2 Power Requirements Three (3) Phase Requirements MODEL VOLTAGE WIRE SERVICEMINIMUM WIRESIZE AWG (mm) AMPS (per leg) 1814E 14kW 208 3
2-4 1. Once the fryer has been positioned at the frying station, use a carpenter’s level placed across the top of the frypot to verify that the uni
2-5 Clean frypot(s) as follows before filling with oil for the first time and at least once a month thereafter: 1. Before switching the fryer "
3–1 FRYMASTER 1814E SERIES ELECTRIC FRYER CHAPTER 3: OPERATING INSTRUCTIONS 3.1 Equipment Setup and Shutdown Procedures Setup DANGER Never op
3–2 melt the shortening. It may be necessary to add solid shortening to bring the level up to the proper mark after the packed shortening has melted.
4-1 FRYMASTER 1814E SERIES ELECTRIC FRYER CHAPTER 4: FILTRATION INSTRUCTIONS WARNING Drawings and photos used in this manual are intended to illustr
4-2 the oil or shortening, Frymaster recommends that a Frymaster filter cone holder and filter cone be used when a filter machine is not available. I
4-3 4.3.1 Filter Components Filter paper is held in place by a hold-down ring. Oil moves through the paper, leaving behind impurities. 1. Filte
4-4 4.3.2 Assembling the Filter 1. Place the support grid in the bottom of filter pan. 2. Put one filter paper sheet on top of the sup
NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS MANITOWOC FOOD SERVICE EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PAR
4-5 4.3.2 Assembling the Filter (cont.) 4. Sprinkle 8 ounces (227g) of filter powder on the filter sheet. Ensure the powder covers the filter pap
4-6 4.3.3 Installing the Filter 1. Slide the filter inside the fryer cabinet. Ensure the male-female pickup tubes are fully engaged. Ensure the f
4-7 4.4.2 Filtering Tools Assemble tools to be used for filtering. These are supplied with the filter starter kit included with the fryer/filter sys
4-8 4.5 Operating the Filter 4.5.1 Filter Operation See Section 4.3.2, Assembling the Filter, and Section 4.3.3, Installing the Filter, for the
4-9 4.5.1 Filter Operation (cont.) 5. After all oil has drained from the frypot into the filter pan, turn the yellow handle (right) to open the o
4-10 4.5.1 Filter Operation (cont.) 11. Lower the elements into the frypot. 12. Replace the basket support rack, using care not to splash hot oil.
4-11 4.6 Draining and Disposing of Waste Oil When your oil has reached the end of its usable life, drain the oil into an appropriate METAL contain
5–1 FRYMASTER 1814E SERIES ELECTRIC FRYER CHAPTER 5: PREVENTATIVE MAINTENANCE 5.1 Cleaning the Fryer DANGER The crumb tray in fryers equipped wi
5–2 A. Completely drain the oil from the fryer into a metal stockpot of sufficient size to safely hold the entire contents of the frypot for disposal
5-3 • Verify that component box and contactor box components (i.e. computer/controller, relays, interface boards, transformers, contactors, etc.) are
DANGER The front ledge of this appliance is not a step! Do not stand on the appliance. Serious injury can result from slips or contact with the ho
5–4 5.3 Stainless Steel Care DANGER DO NOT let water splash into the tank of hot oil. It will splatter and can cause severe burns. All stainless
6-1 FRYMASTER 1814E SERIES ELECTRIC FRYER CHAPTER 6: OPERATOR TROUBLESHOOTING 6.1 Introduction This section provides an easy reference guide to so
6-2 6.2 Troubleshooting 6.2.1 Controller and Heating Problems Problem Probable Causes Corrective Action Controller won't activate. A. Powe
6-3 6.2.2 Filtration Problems Problem Probable Causes Corrective Action Filter pump won't start. A. Power cord is not plugged in or circuit
6-4 6.3 User Replaceable Parts User Replaceable Parts Part Number Description 230-8464 Basket hanger 21814E 230-8319 Basket hanger 1814E/RE14/18
THIS PAGE INTENTIONALLY LEFT BLANK
Frymaster, 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-688-2200 (Tech Support) 1-318-219-7135 PRINTED IN
FINDING YOUR WAY AROUND THE FRYMASTER 1814E SERIES ELECTRIC FRYER TYPICAL CONFIGURATION (31814E SHOWN) NOTE: The appearance of your frye
i 1814E SERIES ELECTRIC FRYER Installation and Operation Manual TABLE OF CONTENTS CHAPTER 1: Introduction 1.1 General Information ...
1-1 FRYMASTER 1814E SERIES ELECTRIC FRYER CHAPTER 1: INTRODUCTION 1.1 General This manual covers all configurations of 1814E series electric fryer
1-2 harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency e
1-3 electrical precautions involved, and have complied with all requirements of applicable national and local codes. QUALIFIED SERVICE PERSONNEL Qua
2-1 FRYMASTER 1814E SERIES ELECTRIC FRYER CHAPTER 2: INSTALLATION INSTRUCTIONS 2.1 General Proper installation is essential for the safe, efficien