Frymaster 45 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Friteuses Frymaster 45. Frymaster 45 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 52
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Series 35, 45,
CF & J1C
Frymaster, a member of the Commercial Food Equipment Service Association, recommends
using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633 NOVEMBER 2003
PRINTED IN THE USA
*8196003*
*8196003**8196003*
*8196003*
Master Jet Series Atmospheric Gas
Fryers
Installation and Operation Manual
Vue de la page 0
1 2 3 4 5 6 ... 51 52

Résumé du contenu

Page 1 - *8196003**8196003*

Series 35, 45, CF & J1C Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians.

Page 2

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: INTRODUCTION 1-6 1.7 Definitions QUALIFIED AND/OR AUTHORIZED OPERATING PERSONNEL Qualified/a

Page 3

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-1 2.1 General Installation Requirements Qualified, licensed, and/

Page 4 - TABLE OF CONTENTS

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-2 2.1 General Installation Requirements (cont.) CLEARANCE AND VE

Page 5 - CHAPTER 1: INTRODUCTION

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-3 2.1 General Installation Requirements (cont.) NATIONAL CODE RE

Page 6 - 1.3 Safety Information

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-4 2.1 General Installation Requirements (cont.) FCC COMPLIANCE (

Page 7 - MJ2CFEMBLSC

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-5 2.3 Pre-Connection Preparations (cont.) DANGER Do not attach

Page 8

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-6 2.3 Pre-Connection Preparations (cont.) 6. Verify the minimum

Page 9

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-7 2.4 Connection to Gas Line DANGER Before connecting new pip

Page 10 - 1.7 Definitions

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-8 2.4 Connection to Gas Line (cont.) Gas Connection Pipe Sizes

Page 11

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-9 2.4 Connection to Gas Line (cont.) DANGER All connections mus

Page 12

NOTICE This appliance is intended for professional use only and is to be operated by qualified personnel only. A Frymaster/DEAN Factory Authorized S

Page 13

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-10 2.4 Connection to Gas Line (cont.) 5. Check the thermostat

Page 14 - 2.2 Caster/Leg Installation

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-11 2.5 Converting to Another Gas Type (cont.) CE Gas Conversio

Page 15

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2-12 2.5 Converting to Another Gas Type (cont.) Non-CE Gas Conve

Page 16 - Table 2: Non-CE Standard

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS 3-1 3.1 Start-Up Procedure DANGER Never operate this appliance with

Page 17 - 2.4 Connection to Gas Line

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS 3-2 3.1 Start-Up Procedure (cont.) Ensure that the following steps ar

Page 18

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS 3-3 3.1 Start-Up Procedure (cont.) LIGHTING THE PILOT ON NON-CE FRYER

Page 19 - Burner Manifold Gas Pressures

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS 3-4 3.1 Start-Up Procedure (cont.) 2. If fryer is equipped with a pi

Page 20

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS 3-5 3.2 Boiling-Out the Frypot To ensure that the frypot is free of a

Page 21

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 3: OPERATING INSTRUCTIONS 3-6 3.2 Boiling-Out the Frypot (cont.) 6. Place the fryer into opera

Page 22

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-1 4.1 Draining and Manual Filtering WARNING The on-site supervisor

Page 23 - 3.1 Start-Up Procedure

DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equi

Page 24 - Insert match or taper through

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-2 4.1 Draining and Manual Filtering (cont.) 2. Position a metal c

Page 25 - Lighting the Pilot

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-3 4.2 Filter Magic II Filtration System Operation The Filter Magic

Page 26

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-4 4.2 Filter Magic II Filtration System Operation (cont.) 3. Wipe

Page 27 - recommends

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-5 4.2 Filter Magic II Filtration System Operation (cont.) 6. Spri

Page 28 - 3.3 Shutting the Fryer Down

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-6 4.2 Filter Magic II Filtration System Operation (cont.) OPERATIO

Page 29

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-7 4.2 Filter Magic II Filtration System Operation (cont.) DANGER

Page 30

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 4: FILTRATION INSTRUCTIONS 4-8 4.2 Filter Magic II Filtration System Operation (cont.) 5. Rem

Page 31

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-1 5.1 Fryer Preventive Maintenance Checks and Services DAILY CHECK

Page 32

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-2 5.1 Fryer Preventive Maintenance Checks and Services (cont.) WE

Page 33

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-3 5.1 Fryer Preventive Maintenance Checks and Services (cont.) Cl

Page 34

Master Jet Series Atmospheric Gas Fryers TABLE OF CONTENTS PAGE # CHAPTER 1: General Information 1.1 Applicability and Valid

Page 35

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-4 5.1 Fryer Preventive Maintenance Checks and Services (cont.) Ch

Page 36

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-5 5.1 Fryer Preventive Maintenance Checks and Services (cont.) 4.

Page 37

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-6 5.3 Annual/Periodic System Inspection This appliance should be

Page 38

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-7 5.3 Annual/Periodic System Inspection (cont.) Built-In Filtrati

Page 39

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-1 6.1 Introduction This chapter provides an easy reference guide t

Page 40

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-2 6.2 Troubleshooting Fryers with Solid State (Analog), Digital or

Page 41 - Services

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-3 6.2 Troubleshooting Fryers with Solid State (Analog), Digital or

Page 42

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-4 6.3 Troubleshooting Fryers with Thermostat Controls PROBLEM Pro

Page 43

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-5 6.4 Troubleshooting the Built-In Filtration System PROBLEM PROB

Page 44 - 6.1 Introduction

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-6 6.4 Troubleshooting the Built-In Filtration System (cont.) PROB

Page 45 - Controllers

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: INTRODUCTION 1-1 1.1 Applicability and Validity All Master Jet Series Atmospheric gas fryer m

Page 46 - Controllers (cont.)

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-7 6.4 Troubleshooting the Built-In Filtration System (cont.) A.

Page 47

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 6: OPERATOR TROUBLESHOOTING 6-8 6.6 Replacing the Controller or Controller Wiring Harness 1.

Page 48

Frymaster L.L.C, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 T

Page 49

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: INTRODUCTION 1-2 1.3 Safety Information Before attempting to operate your unit, read the ins

Page 50

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: INTRODUCTION 1-3 1.5 Equipment Description Master Jet Series Atmospheric gas fryers are desi

Page 51

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: INTRODUCTION 1-4 1.5.1 Option Designations (cont.) Model specific designators: G: Thermost

Page 52 - NOVEMBER 2003

MASTER JET SERIES ATMOSPHERIC GAS FRYERS CHAPTER 1: INTRODUCTION 1-5 1.5.2 Model Applications (cont.) All models except J1C Series fryers may be