Frymaster, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. 24-Hour Service Hotline 1-
2-3 NOTICE If this appliance is permanently connected to fixed wiring, it must be connected by means of copper wires having a temperature rating of n
2-4 NOTE: If you need to relocate a fryer installed with legs, remove all weight from each leg before moving. If a leg becomes damaged, contact yo
3–1PRO SERIES ELECTRIC FRYERSCHAPTER 3: OPERATING INSTRUCTIONS3.1 Equipment Setup and Shutdown ProceduresSetup DANGERNever operate the appliance wit
3–2Shutdown1. Turn the fryer off.2. Filter the cooking oil/shortening and clean the fryers (See Chapters 4 and 5).3. Place the frypot covers on the f
3–3 CAUTIONIf this is the first time the fryer is being used after installation, refer to the frypot Boil-Out Procedureon Page 5-2.Refer to the separa
4-1PRO SERIES ELECTRIC FRYERSCHAPTER 4: FILTRATION INSTRUCTIONS WARNINGThe on-site supervisor is responsible for ensuring that operators are made awa
4-23. Open the drain valve slowly to avoid splattering. If the drain valve becomes clogged with foodparticles, use the Fryer’s Friend (poker-like to
4-34.2.1 Preparation for Use with Filter Paper or Filter Pad1. Pull the filter pan out from the cabinetand remove the crumb tray, hold-downring, fil
4-45. When the hold-down ring is in position,if using filter paper, sprinkle one cup offilter powder evenly over the paper. (SeeFigure 4)If using a f
4-54. Replace the Magnasol filter assembly in the filter pan, ensuring that the fitting on the bottom ofthe assembly is securely seated in the port i
NOTICE IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS ENODIS EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED DIRE
4-62. Install the Power Shower by removingthe basket support rack from the frypot.Raise the element assembly to the upposition and snap the power sho
4-7 WARNINGThe filter pump is equipped with a manual reset switch in case the filter motoroverheats or an electrical fault occurs. If this switch tri
4-84.4 Disassembly and Reassembly of the Magnasol FilterDissassembly1. Grasp the frame with your thumbs on the handles at the corner of the assembly
4-9Steps 1 and 2 - Stack outer screensand insert edges into frame.Step 3 - Insert grid between screensafter screens have been positioned inframe.Step
5–1PRO SERIES ELECTRIC FRYERSCHAPTER 5: PREVENTATIVE MAINTENANCE5.1 Cleaning the Fryer DANGERThe crumb tray in fryers equipped with a filter system m
5–2shortening or other blockages. Rinse with hot water, dry thoroughly, and reinstall the plugs beforeusing.Clean-out PlugsGasket DANGERFailure to re
5-34. Simmer the solution for 45 minutes to one hour. Do not allow the water level to drop below thebottom oil-level line in the frypot during the b
5–45.3 Annual/Periodic System InspectionThis appliance should be inspected and adjusted periodically by qualified service personnel aspart of a regula
5-5• Verify that all O-rings and seals (including those on the Power Shower and on quick-disconnectfittings) are present and in good condition. Repl
6-1PRO SERIES ELECTRIC FRYERSCHAPTER 6: OPERATOR TROUBLESHOOTING6.1 IntroductionThis section provides an easy reference guide to some of the common p
DANGER Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other appliance. DANGER The crumb tray in
6-26.2 Troubleshooting6.2.1 Control and Heating ProblemsProblem Probable Causes Corrective ActionA. Power cord is not plugged in orcircuit breaker is
6-3Problem Probable Causes Corrective ActionFryer repeatedlycycles on and offwhen first started.Fryer is in melt-cycle mode.This is normal for fryers
6-4ProblemProbable Causes Corrective ActionFryer heats untilhigh limit tripswithout heatindicator ON.Contactor or controller has failed.Call FASC.Frye
6-5Problem Probable Causes Corrective ActionCM III displayshows .Fryer is more than 21ºF (12ºC) abovesetpoint.This display is normal if the fryersetpo
6-6Problem Probable Causes Corrective ActionDigital controllerdisplay is in wrongtemperature scale(Fahrenheit orCelsius).Incorrect display option sele
6-76.2.3 Basket Lift ProblemsProblem Probable Causes Corrective ActionBasket liftmovement is noisy,jerky, or erratic.Lack of lubrication on basket lif
6-8Problem Probable Causes Corrective ActionFilter pump runs,but oil return is veryslow and bubblingoil comes out of thePower Shower.A. Improperly in
THIS PAGE INTENTIONALLY LEFT BLANK
Frymaster, L.L.C., 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106T
iPro Series Electric Fryers Installation and Operation ManualTABLE OF CONTENTSCHAPTER 1: Introduction1.1 General Information ...
1-1PRO SERIES ELECTRIC FRYERSCHAPTER 1: INTRODUCTION1.1 GeneralRead the instructions in this manual thoroughly before attempting to operate this equi
1-21.3 Computer InformationThis equipment has been tested and found to comply with the limits for a Class A digital device,pursuant to Part 15 of the
1-31.6 Service InformationFor non-routine maintenance or repairs, or for service information, contact your local FrymasterAuthorized Service Center (F
2-1 PRO SERIES ELECTRIC FRYERS CHAPTER 2: INSTALLATION INSTRUCTIONS 2.1 General Proper installation is essential for the safe, efficient, trouble-
2-2 DANGER Do not attach an apron drainboard to a single fryer. The fryer may become unstable, tip over, and cause injury. The appliance area must