Frymaster SM80 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Friteuses Frymaster SM80. Frymaster SM80 User Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1

Price: $8.00 Service Hotline 1-318-865-1711 819-5894MAY 2007 Dean Millivolt Gas Fryers (CE) Installation & Operation Manual Model

Page 2

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2-2 2.2 General (cont.) Where conflicts exist between instructions and informatio

Page 3

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2-3 2.4 Rating Plate DANGER Fryers MUST be connected ONLY to the gas-type identif

Page 4 - TABLE OF CONTENTS

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2-4 2.5 Pre-Installation (cont.) C. Installation Standards 1. CE/EXPORT STANDA

Page 5 - TABLE OF CONTENTS (CONT.)

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2-5 2.8 Conversion of Units Pressure: 1 mbar = 10,2 mm W.C. = 0,4-inch W.C. 20 m

Page 6 - CHAPTER 1: INTRODUCTION

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-1 3.1 Installing the Fryer A. Initial Installation: If installed with leg

Page 7 - 1.5 Service Personnel

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-2 3.2 Leg and Caster Installation (cont.) B. Leg and Rigid Caster Installa

Page 8

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-3 3.3 Leveling the Fryer (cont.) Rigid Casters (Only) 1. Install the rigi

Page 9 - 2.2 General

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-4 3.3 Leveling the Fryer (cont.) NOTE: The installation must be inspected a

Page 10 - 2.3 Principles of Operation

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-5 3.4 Gas Connections (cont.) NATIONAL CODE REQUIREMENTS This equipment is

Page 11 - 2.5 Pre-Installation

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-6 3.4 Gas Connections (cont.) DANGER "Dry-firing" your unit will

Page 12 - C. Installation Standards

i Please read all sections of this manual and retain for future reference. NOTICE This appliance is intended for professional use only and is to be

Page 13 - 2.8 Conversion of Units

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-7 3.4 Gas Connections (cont.) 3. If a vent line from the gas pressure regu

Page 14 - 3.1 Installing the Fryer

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-8 3.4 Gas Connections (cont.) WARNING Do not attach accessories to this f

Page 15 - 3.3 Leveling the Fryer

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-9 3.6 Gas Inputs Nominal Heat Inputs (Qn), Gas Type, Orifice Size, Part Num

Page 16

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-10 3.6 Gas Inputs (cont.) A. Adjustments for different gases are as foll

Page 17 - 3.4 Gas Connections

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-11 3.7 Gas Conversion Procedures DANGER This appliance was configured at t

Page 18 - 3.4 Gas Connections (cont.)

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-12 3.7 Gas Conversion Procedures (cont.) Conversions can only be executed b

Page 19

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 3: INSTALLATION INSTRUCTIONS 3-13 3.8 Gas Conversion Components Use the following components to convert fr

Page 20

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 4: FRYER OPERATION 4-1 4.1 Initial Startup WARNING The on-site supervisor is responsible for ensuring th

Page 21

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 4: FRYER OPERATION 4-2 4.1.1 Pilot Lighting Procedures Initial Pilot Lighting: All Dean fryers are tested,

Page 22 - 3.6 Gas Inputs

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 4: FRYER OPERATION 4-3 4.1.1 Pilot Lighting Procedures (cont.) 9. If the pilot does not stay lit, depress

Page 23 - 3.6 Gas Inputs (cont.)

ii DANGER The front ledge of the fryer is not a step. Do not stand on the fryer. Serious injury can result from slips or contact with the hot oil.

Page 24

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 4: FRYER OPERATION 4-4 4.2 Boil-Out Procedure (cont.) 6. The burners will heat the boil-out solution to a

Page 25 - Detail A

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 4: FRYER OPERATION 4-5 4.3 Final Preparation DANGER Do not go near the area directly over the flue outlet

Page 26 - 3.9 Electrical Connections

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 4: FRYER OPERATION 4-6 4.3.2 Opening: Beginning the Work Day At the beginning of each work day, always che

Page 27 - CHAPTER 4: FRYER OPERATION

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 4: FRYER OPERATION 4-7 4.3.3 Filtering Basics (cont.) e When completing a filter cycle, always close the

Page 28 - Honeywell gas valve

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 5: PREVENTATIVE MAINTENANCE 5-1 5.1 General DANGER Never attempt to clean the fryer during the cooking

Page 29 - 4.2 Boil-Out Procedure

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 5: PREVENTATIVE MAINTENANCE 5-2 5.1.3 Periodic The fryer should be inspected and adjusted periodically by

Page 30

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 6: TROUBLESHOOTING 6-1 6.1 General DANGER Hot cooking oil/shortening will cause severe burns. Never at

Page 31 - 4.3 Final Preparation

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 6: TROUBLESHOOTING 6-2 6.3 Main Burner Malfunction A. Main burner will not come "ON": no gas de

Page 32

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 6: TROUBLESHOOTING 6-3 6.4 Millivolt Wiring Diagram (CE) WARNINGDO NOT CONNECT ANY EXTERNALELECTRICAL PO

Page 33

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 6: TROUBLESHOOTING 6-4 6.5 Recommended Spare Parts Commonly replaced parts in older Dean Millivolt Gas (CE

Page 34 - 5.1 General

i Dean Millivolt Gas Fryers (CE) Installation & Operation Manual TABLE OF CONTENTS Page # 1. INTRODUCTION 1-1 1.1 Applicability an

Page 35

Dean, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-8

Page 36 - CHAPTER 6: TROUBLESHOOTING

ii Dean Millivolt Gas Fryers (CE) Installation & Operation Manual TABLE OF CONTENTS (CONT.) Page # 4. FRYER OPERATIONS 4-1 4.1 Init

Page 37 - 6.3 Main Burner Malfunction

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 1: INTRODUCTION 1-1 1.1 Applicability and Validity Dean Super Marathon and Super Runner Series gas model

Page 38 - HONEYWELL CE

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 1: INTRODUCTION 1-2 1.4 Safety Information Before attempting to operate your unit, read the instructions i

Page 39 - 6.5 Recommended Spare Parts

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 1: INTRODUCTION 1-3 1.5.1 Definitions (cont.) B. Qualified Installation Personnel 1. Qualified/authoriz

Page 40 - MAY 2007

DEAN MILLIVOLT GAS FRYERS (CE) CHAPTER 2: IMPORTANT INFORMATION 2-1 2.1 Receiving and Unpacking Equipment A. Check that the container is uprigh

Modèles reliés SM50 | SM40 |

Commentaires sur ces manuels

Pas de commentaire