Frymaster Gas Rethermalizers FBRA18 Series Manuel d'utilisateur Page 21

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 62
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 20
4-4
3. Place the gas valve in the ON position. Place the controller power switch in the ON position.
When the burner lights and continues to burn, compare the indicated pressure to the table
below.
Burner Manifold Gas
Pressures
Gas Pressure
Natural
3.5" W.C.
0.8 kPa
LP
8.25" W.C.
2.5 kPa
4. If necessary, adjust the burner gas pressure by removing the cap from the gas valve regulator
and turning the regulator screw to obtain the correct pressure. When the correct pressure is
obtained, reinstall the cap.
5. Place the controller power switch and the gas valve in the OFF position. Remove the fitting
from the pressure tap hole and reinstall the pressure tap plug.
Vue de la page 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 61 62

Commentaires sur ces manuels

Pas de commentaire