Frymaster/Dean, a member of the Commercial Food Equipment Service Association,
recommends using CFESA Certified Technicians.
24-Hour Service Hotline 1-800-551-8633 AUGUST 2007
PRINTED IN THE USA
YSCFC24 Series Flatbottom Gas Fryers
Installation & Operation Manual
Model YSCFC24 Systems
with Built-In Filtration
*8196352*
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - *8196352*

Frymaster/Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. 24-Hour Service

Page 2

2-2 2.3 STANDARDS (cont.) E. NFPA Standards #96 and #211 (latest edition) National Fire Protection Association 470 Atlantic Avenue Boston, MA 021

Page 3 - COMPUTERS

3-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3.1 UNPACKING Check that the container is upright. Use outward pry

Page 4 - TABLE OF CONTENTS

3-2 3.5 GAS CONNECTION The gas supply (service) line must be the same size or greater than the inlet line of the appliance. YSCFC24 Series gas frye

Page 5 - 1.1 OPERATING CONTROLS

3-3 3.5.5 Flexible Couplings, Connectors If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must

Page 6 - 1.6 ORDERING PARTS

3-4 Figure 1. Retainer latches securing filter pan.3.7 SYSTEM INSTALLATION INSTRUCTIONS 1. This system consists of a 2424G fryer with a built-in fi

Page 7 - 1.8 SAFETY INFORMATION

3-5 3.7 SYSTEM INSTALLATION INSTRUCTIONS (CONT.) 6. With the cabinets together, carefully slide the drainpipe halfway into the rubber boot. Conne

Page 8 - 1.9 SERVICE PERSONNEL

3-6 3.7 SYSTEM INSTALLATION INSTRUCTIONS (CONT.) 11. Prior to performing start-up, ensure the drainpipe connected during assembly is not blocking ei

Page 9 - CHAPTER 2: PRE-INSTALLATION

4-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 4: STARTUP AND OPERATING PROCEDURES 4.1 CLEANING Note: All procedures should be performed as ins

Page 10 - 2.5 ALTITUDE

4-2 4.2 INITIAL STARTUP YSCFC24 Series gas fryers are tested, adjusted, and calibrated before leaving the factory. Adjustments to assure proper ope

Page 11 - 3.4 LEVELING

4-3 4.3 ELECTRONIC SPARK IGNITION WARNING NEVER USE A MATCH OR TAPER TO LIGHT THIS IGNITION SYSTEM! 1. Turn off the electric power. 2. Turn the

Page 12 - 3.5 GAS CONNECTION

Please read all sections of this manual and retain for future reference. This product has been certified as commercial cooking equipment and MUST be

Page 13 - 3.6 ELECTRICAL CONNECTIONS

4-4 4.4 ADJUSTING BURNERS (cont.) 4.5 FILLING THE VAT WITH SHORTENING DANGER NEVER MELT A SOLID BLOCK OF SHORTENING BY PLACING IT WHOLE INTO T

Page 14 - These frypots must mate

5-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 5: DAILY OPERATION/FILTRATION 5.1 OPENING At opening, check the fryer for: 1. Combination or m

Page 15

5-2 5.4 FILTER PREPARATION 1. Assemble the filter pan, ensuring all components are clean and dry. When assembling the filter pan, follow company

Page 16

5-3 5.4 FILTER PREPARATION (cont.) 6. Replace the filter pan lid. Ensure pick-up tube emerges through hole in pan lid. Ensure filter system h

Page 17 - 4.1 CLEANING

5-4 5.5 FILTERING INSTRUCTIONS (cont.) A. Assemble tools for filtering. All except the squeegee are supplied with the filter starter kit: 1. Sque

Page 18 - 4.2 INITIAL STARTUP

5-5 5.6 FILTER OPERATION 1. Turn the fryer OFF. 2. Immediately before draining, use correct straining method to collect large debris suspende

Page 19 - 4.4 ADJUSTING BURNERS

5-6 FILTER OPERATION (cont.) 5. Move the yellow oil-return handle from right to left to open the oil-return line. The filter pump will activate. N

Page 20 - 4.6 FINAL PREPARATION

5-7 5.7 Disassembling/Assembling and Cleaning the Magnum Filter Leaf YSCFC24 Series fryers with UFF filtration come equipped with a filter leaf, whic

Page 21 - 5.3 FILTERING

5-8 5.7.2 Cleaning the Filter Leaf Assembly Clean the two seal frame pieces, screens and grid using a good quality degreaser and hot water from a sp

Page 22 - Placing the crumb screen

5-9 5.9 FILTER TROUBLESHOOTING The problems and possible solutions covered are those most commonly encountered. Pump won'tstart.y Return val

Page 23 - 5.5 FILTERING INSTRUCTIONS

DANGER The front ledge of the fryer is not a step. Do not stand on the fryer. Serious injury can result from slips or contact with the hot oil.

Page 24 - FAILURE

6-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE Consult the company Operations Manual for cleaning and maintenance ins

Page 25

6-2 6.4 Periodic The fryer should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance pro

Page 26 - FILTER OPERATION (cont.)

6-3 6.4 Periodic (cont.) • Check filtration system integrity as follows: − With the filter pan empty, place each oil return handle, one at a tim

Page 27

7-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 7: TROUBLESHOOTING FACTORY APPROVAL MUST BE OBTAINED PRIOR TO ANY WARRANTY WORK BEING DONE OR FRY

Page 28 - 5.8 CLOSING

7-2 7.2 MAIN BURNER MALFUNCTIONS PROBLEM CORRECTIVE ACTION Main burner will not come on even though air blower is in operation; no gas pressure at

Page 29 - 5.9 FILTER TROUBLESHOOTING

7-3 7.3 INDICATOR LIGHTS (cont.) When turning the power switch "ON" and resetting the safety (reset) switch, check for the following: LIG

Page 30

7-4 7.5 WIRING DIAGRAMS 7.5.1 YSCFC Wiring Diagram (with filter)

Page 31 - 6.4 Periodic

7-5 7.5.2 YSCFC Wiring Diagram (non-filter)

Page 32 - 6.5 Stainless Steel Care

7-6 7.5.3 YSCFC24 Filter Wiring

Page 33 - CHAPTER 7: TROUBLESHOOTING

THIS PAGE INTENTIONALLY LEFT BLANK

Page 34 - 7.3 INDICATOR LIGHTS

Y24G Series Flatbottom Gas Fryers INSTALLATION & OPERATION MANUAL TABLE OF CONTENTS Page # 1. DESCRIPTION AND SPECIFICA

Page 35

Frymaster, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL

Page 36 - 7.5 WIRING DIAGRAMS

1-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: DESCRIPTION AND SPECIFICATIONS The YSCFC24 Series gas fryers are energy-efficient, gas-fired un

Page 37

1-2 1.3 RATING PLATE The rating plate can be found inside the fryer door. Information on this plate includes the model and serial numbers, as well

Page 38 - 7.5.3 YSCFC24 Filter Wiring

1-3 1.7 COMPUTER INFORMATION This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of

Page 39

1-4 1.9 SERVICE PERSONNEL 1.9.1 Definitions A. Qualified and/or Authorized Operating Personnel 1. Qualified/authorized operating personnel are

Page 40 - AUGUST 2007

2-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 2: PRE-INSTALLATION 2.1 GENERAL A. Installation of any gas-fired equipment should be performed