Frymaster/Dean, a member of the Commercial Food Equipment Service Association, recommends using CFESA Certified Technicians. 24-Hour Service
2-2 2.3 STANDARDS (cont.) E. NFPA Standards #96 and #211 (latest edition) National Fire Protection Association 470 Atlantic Avenue Boston, MA 021
3-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 3: INSTALLATION INSTRUCTIONS 3.1 UNPACKING Check that the container is upright. Use outward pry
3-2 3.5 GAS CONNECTION The gas supply (service) line must be the same size or greater than the inlet line of the appliance. YSCFC24 Series gas frye
3-3 3.5.5 Flexible Couplings, Connectors If the unit is to be installed with flexible couplings and/or quick-disconnect fittings, the installer must
3-4 Figure 1. Retainer latches securing filter pan.3.7 SYSTEM INSTALLATION INSTRUCTIONS 1. This system consists of a 2424G fryer with a built-in fi
3-5 3.7 SYSTEM INSTALLATION INSTRUCTIONS (CONT.) 6. With the cabinets together, carefully slide the drainpipe halfway into the rubber boot. Conne
3-6 3.7 SYSTEM INSTALLATION INSTRUCTIONS (CONT.) 11. Prior to performing start-up, ensure the drainpipe connected during assembly is not blocking ei
4-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 4: STARTUP AND OPERATING PROCEDURES 4.1 CLEANING Note: All procedures should be performed as ins
4-2 4.2 INITIAL STARTUP YSCFC24 Series gas fryers are tested, adjusted, and calibrated before leaving the factory. Adjustments to assure proper ope
4-3 4.3 ELECTRONIC SPARK IGNITION WARNING NEVER USE A MATCH OR TAPER TO LIGHT THIS IGNITION SYSTEM! 1. Turn off the electric power. 2. Turn the
Please read all sections of this manual and retain for future reference. This product has been certified as commercial cooking equipment and MUST be
4-4 4.4 ADJUSTING BURNERS (cont.) 4.5 FILLING THE VAT WITH SHORTENING DANGER NEVER MELT A SOLID BLOCK OF SHORTENING BY PLACING IT WHOLE INTO T
5-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 5: DAILY OPERATION/FILTRATION 5.1 OPENING At opening, check the fryer for: 1. Combination or m
5-2 5.4 FILTER PREPARATION 1. Assemble the filter pan, ensuring all components are clean and dry. When assembling the filter pan, follow company
5-3 5.4 FILTER PREPARATION (cont.) 6. Replace the filter pan lid. Ensure pick-up tube emerges through hole in pan lid. Ensure filter system h
5-4 5.5 FILTERING INSTRUCTIONS (cont.) A. Assemble tools for filtering. All except the squeegee are supplied with the filter starter kit: 1. Sque
5-5 5.6 FILTER OPERATION 1. Turn the fryer OFF. 2. Immediately before draining, use correct straining method to collect large debris suspende
5-6 FILTER OPERATION (cont.) 5. Move the yellow oil-return handle from right to left to open the oil-return line. The filter pump will activate. N
5-7 5.7 Disassembling/Assembling and Cleaning the Magnum Filter Leaf YSCFC24 Series fryers with UFF filtration come equipped with a filter leaf, whic
5-8 5.7.2 Cleaning the Filter Leaf Assembly Clean the two seal frame pieces, screens and grid using a good quality degreaser and hot water from a sp
5-9 5.9 FILTER TROUBLESHOOTING The problems and possible solutions covered are those most commonly encountered. Pump won'tstart.y Return val
DANGER The front ledge of the fryer is not a step. Do not stand on the fryer. Serious injury can result from slips or contact with the hot oil.
6-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 6: PREVENTATIVE MAINTENANCE Consult the company Operations Manual for cleaning and maintenance ins
6-2 6.4 Periodic The fryer should be inspected and adjusted periodically by qualified service personnel as part of a regular kitchen maintenance pro
6-3 6.4 Periodic (cont.) • Check filtration system integrity as follows: − With the filter pan empty, place each oil return handle, one at a tim
7-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 7: TROUBLESHOOTING FACTORY APPROVAL MUST BE OBTAINED PRIOR TO ANY WARRANTY WORK BEING DONE OR FRY
7-2 7.2 MAIN BURNER MALFUNCTIONS PROBLEM CORRECTIVE ACTION Main burner will not come on even though air blower is in operation; no gas pressure at
7-3 7.3 INDICATOR LIGHTS (cont.) When turning the power switch "ON" and resetting the safety (reset) switch, check for the following: LIG
7-4 7.5 WIRING DIAGRAMS 7.5.1 YSCFC Wiring Diagram (with filter)
7-5 7.5.2 YSCFC Wiring Diagram (non-filter)
7-6 7.5.3 YSCFC24 Filter Wiring
THIS PAGE INTENTIONALLY LEFT BLANK
Y24G Series Flatbottom Gas Fryers INSTALLATION & OPERATION MANUAL TABLE OF CONTENTS Page # 1. DESCRIPTION AND SPECIFICA
Frymaster, 8700 Line Avenue, PO Box 51000, Shreveport, Louisiana 71135-1000 Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL
1-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 1: DESCRIPTION AND SPECIFICATIONS The YSCFC24 Series gas fryers are energy-efficient, gas-fired un
1-2 1.3 RATING PLATE The rating plate can be found inside the fryer door. Information on this plate includes the model and serial numbers, as well
1-3 1.7 COMPUTER INFORMATION This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
1-4 1.9 SERVICE PERSONNEL 1.9.1 Definitions A. Qualified and/or Authorized Operating Personnel 1. Qualified/authorized operating personnel are
2-1 YSCFC24 SERIES FLATBOTTOM GAS FRYERS CHAPTER 2: PRE-INSTALLATION 2.1 GENERAL A. Installation of any gas-fired equipment should be performed