24G SERIES FLATBOTTOM GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-10
8. Remove the sensor bulb guard to access the
probe and high-limit. Current production
systems have a sensor bulb clamp that must
be removed prior to removing the probe or
high-limit from the frypot.
9. On the sensor bulb being removed, loosen
and unscrew completely the compression
nut, then the pass-through nut from the
frypot. Carefully remove the sensor bulb
from the frypot, being careful not to damage
the remaining sensor bulb.
10. If removing the high-limit, remove the
screws securing it to the wireway box.
Mark and remove the wiring from the high-
limit housing.
High-limit.
11. Reverse steps to install new temperature probe or high-limit. If reinstalling high-limit, ensure the
capillary tube is properly routed around the temperature probe before tightening (see photo, Step
#8). Reconnect wiring removed from defective high-limit.
Temperature probe. High-limit.