Frymaster YSCF14G Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Friteuses Frymaster YSCF14G. Frymaster YSCF14G User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 26
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
Frymaster and Dean, members of the Commercial Food Equipment Service Association,
recommend using CFESA Certified Technicians.
www.frymaster.com
24-Hour Service Hotline 1-800-551-8633
YSCF14G Series Gas Fryers
Installation & Operation Manual
YSCF14G Series with Built-In Filtration
*8196132*
JULY 09
Vue de la page 0
1 2 3 4 5 6 ... 25 26

Résumé du contenu

Page 1 - YSCF14G Series Gas Fryers

Frymaster and Dean, members of the Commercial Food Equipment Service Association, recommend using CFESA Certified Technicians. www.frymaster.com 2

Page 2

YSCF14G SERIES GAS FRYERS CHAPTER 2: FRYER OPERATIONS 2-2 2.2 Final Preparation WARNING Do not go near the area directly over the flue outlet wh

Page 3

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-1 WARNING Drawings and photos used in this manual are intended to illustrate operat

Page 4 - YSCF14G

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-2 3.1 General Frymaster YSCF14G Series gas fryers come equipped with a built-in filtr

Page 5 - CHAPTER 1: INSTALLATION

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-3 Assemble the filter as follows: 1. Place the support grid in the bottom of filter

Page 6 - 1.1 Gas Connections (cont.)

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-4 3.2.2 Installing the Filter Slide the filter inside the fryer cabinet. Ensure the m

Page 7

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-5 3.3.2 Filtering Tools Assemble tools to be used for filtering. These are supplied

Page 8 - 1.2 Electrical Connections

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-6 3.4 Operating the Filter (cont.) DANGER Do not drain more than one frypot at a tim

Page 9 - CHAPTER 2: FRYER OPERATIONS

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-7 2. Remove fry baskets from frypot. Prior to filtering, skim any large debris from t

Page 10 - 2.2 Final Preparation

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-8 Push a blue-handled drain lever left to right to drain a frypot. Drain only one frypo

Page 11

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-9 3.4.2 Filter Operation (cont.) 6. Oil will begin to pump from the filter pan into

Page 12 - 3.2 Filtration Preparation

Please read all sections of this manual and retain for future reference. NOTICE This appliance is intended for professional use only and is to be op

Page 13

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-10 3.4.2 Filter Operation (cont.) 9. After all oil is pumped back into the frypot, b

Page 14

YSCF14G SERIES GAS FRYERS CHAPTER 3: BUILT-IN FILTRATION 3-11 3.4.2 Filter Operation (cont.) 12. Do not allow crumbs to accumulate in the crumb

Page 15 - 3.4 Operating the Filter

YSCF14G SERIES GAS FRYERS CHAPTER 4: COMPUTER OPERATION 4–1 NOTE: See the related YUM computer manual (819-6133) for programming instructions.

Page 16

YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-1 5.1 General DANGER Never attempt to clean the fryer during the cooking proce

Page 17

YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-2 5.4 Periodic/Annual This appliance should be inspected and adjusted periodical

Page 18

YSCF14G SERIES GAS FRYERS CHAPTER 5: PREVENTATIVE MAINTENANCE 5-3 5.4 Periodic/Annual (cont.) Built-in Filtration (cont.): • Check filtration

Page 19

Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Support) 1-318-219-7135

Page 20

DANGER Adequate means must be provided to limit the movement of this appliance without depending upon the gas line connection. Single fryers equipp

Page 21

YSCF14G INSTALLATION & OPERATION MANUAL TABLE OF CONTENTS Page # 1. Installation …………………………………………………………………………………1-1 2.

Page 22 - YSCF14G SERIES GAS FRYERS

YSCF14G SERIES GAS FRYERS CHAPTER 1: INSTALLATION 1-1 1.1 Gas Connections DANGER Before connecting new pipe to this appliance the pipe must be b

Page 23

YSCF14G SERIES GAS FRYERS CHAPTER 1: INSTALLATION 1-2 1.1 Gas Connections (cont.) DANGER All connections must be sealed with a joint compound su

Page 24 - 5.4 Periodic/Annual

YSCF14G SERIES GAS FRYERS CHAPTER 1: INSTALLATION 1-3 1.1 Gas Connections (cont.) E. Manifold Pressure: Only qualified personnel should check th

Page 25 - 5.5 Stainless Steel Care

YSCF14G SERIES GAS FRYERS CHAPTER 1: INSTALLATION 1-4 1.1 Gas Connections (cont.) 3. If disconnection of the restraint is necessary, this restra

Page 26 - 819-6132

YSCF14G SERIES GAS FRYERS CHAPTER 2: FRYER OPERATIONS 2-1 2.1 Initial Start-up WARNING The on-site supervisor is responsible for ensuring that o

Commentaires sur ces manuels

Pas de commentaire