OPERATION MANUAL
Frymaster, L.L.C., 8700 Line Avenue
Shreveport, LA 71106
TEL 318-865-1711 FAX 318-868-5987
24-Hour Service Hotline
1-800-551-8633
APRIL 11
*8196797*
FTB-350A 24V TEST BOX
Vue de la page 0
1 2 3 4 5 6 ... 13 14

Résumé du contenu

Page 1 - OPERATION MANUAL

OPERATION MANUAL Frymaster, L.L.C., 8700 Line Avenue Shreveport, LA 71106 TEL 318-865-1711 FAX 318-868-5

Page 2 - TABLE OF CONTENTS

10 B. TEST POWER TO FRYER INTERFACE BOARD 1. Switch the HP690 POWER switch (11) to ON. 2. RELAY POWER indicator (3) should illuminate. 3. Tu

Page 3

11 F. TEST PROBE FAILURE MALFUNCTION 1. Turn on FTB-350A POWER switch (10). 2. Set FTB-350A PROBE switch (7) to SHORT. (a) RELAY POWER indicator

Page 4 - PARTS LIST

12 F3000 TEST PROCEDURE FOR PITCO FRYERS (18WKS FULL, SG18 FULL, SSH75 FULL, SG6H FULL, 14WKS FULL, 7WKS FULL, 7-2WKS SPLIT, E18WKS FULL, SE18 17 KW F

Page 5 - CONTROL PANEL

THIS PAGE INTENTIONALLY LEFT BLANK

Page 6

Frymaster, L.L.C Shipping Address: 8700 Line Avenue, Shreveport, Louisiana 71106 TEL 1-318-865-1711 FAX (Parts) 1-318-219-7140 FAX (Tech Suppor

Page 7

2 TABLE OF CONTENTS

Page 8 - (HP580 and HP590)

3 INTRODUCTION The FTB-350A Test Box is a tester designed to test the F3000 Frymaster cooking controller for correct operating and controlling functi

Page 9 - (HP690)

4 PARTS LIST Item Part Number Description 826-2978 Kit, FTB350A, 120V/24V F3000 Test Box (Includes cable and transformer assembly.) 1 108-3

Page 10

5 CONTROL PANEL 1. Stratify Indicator On during stratify on HP fryers. 7. Right Probe/Thermistor Switch Simulates Temperature 2. Left Heat Indicat

Page 11

6 F3000 TEST PROCEDURE FOR LEGACY FRYMASTER FRYERS (KJ3, 118G, H55, MJ45, 118E/RE80 and FPRE114/117) Ensure the controller is set to LEGACY-FRYMASTER

Page 12

7 D. TEST CONTROLLING FUNCTION 1. Press controller ON/OFF switch to ON (set point = 340°F/171°C). 2. Set FTB-350A PROBE switches (6 & 7) to VAR

Page 13

8 F3000 TEST PROCEDURE FOR HENNY PENNY PRESSURE FRYERS (HP580 and HP590) Ensure the controller is set to HENNY PENNY 580/590/290 FULL using code 7628

Page 14 - APRIL 11

9 n) Leave 2 FLEX at 0. Press the right (X) arrow. o) Leave 2 PRESSURE SOLENOID to OPEN. Press the right (X) arrow. p) Leave :00 at 3 TIME. Press